4 floors~3,200 m2 NIA
HybridPredictive then on-site
Wi-Fi 6Enterprise APs
ReadingM4 corridor

Anonymised engagement. Tenant and landlord names withheld. Heatmap colours described in the report were exported from Ekahau; the graphic on this marketing page is illustrative.

The brief

The MSP had a tender deadline. They had PDF floor plans, a client density guess (open plan plus 8-person meeting rooms) and a preference for ceiling APs on a 5 GHz-led design. They did not want a site visit until after CAT6 was in.

Phase one was a predictive desktop survey in Ekahau AI Pro: wall types from the drawing notes, attenuation libraries, 5 and 6 GHz where the AP hardware allowed, and a BOM the installer could price.

What the model showed

Open plan was easy. The risk was the core: two concrete stair cores, a comms room Faraday-cage effect, and a row of meeting rooms with glass fronts and solid backs. The model wanted APs in the meeting-room ceilings, not only in the floor plate, if Microsoft Teams in those rooms was a requirement.

We also flagged overlapping SSIDs from the landlord’s leftover controller in the basement. That is not a heatmap colour. It is a note on the report: disable or isolate before clients arrive.

What we found after install

The validation walk happened once furniture and plasterboard were in. Two meeting rooms had been built with extra layers the CAD called “partition”. Primary coverage in those rooms missed the -67 dBm target. One AP had been spun 90 degrees on the grid to miss a light fitting.

We did not sell a whole new design. We recommended two extra APs, a mount rotation and a channel tweak. The MSP closed the snagging list with photos and a before/after heatmap in the same .esx project.

Result

The client occupied on the original AP count plus two. The MSP kept the contract. The report listed RSSI, SNR, channel overlap, roaming notes and a switch-port mapping so the next engineer was not guessing.

This pattern is common for office WiFi surveys in Reading, London and along the M4. Predictive first; validation before you sign the building off.

FAQ

Office survey questions

Can you work from PDF plans only?

Yes for a predictive. DWG or a dimensioned PDF is better. If wall types are missing we state the assumptions in the report so the installer is not surprised.

Do you hand over the Ekahau file?

Yes. .esx handover is part of the job unless the MSP asks us to white-label and keep the project.

Office WiFi survey quote

Call 0333 003 4416 or request a quote online.

Get a Quote